The 2017 edition of the national fire protection association nfpa 70 national electrical code nec brings a handful of additions and clarifications to the code pertaining to the permitting and installation of solar pv.
Nec 2017 solar label requirements.
The design of the label must conform to nec 2017 article 110 21 which requires signs to follow ansi z535 4 2011.
Solutions for 2017 2014 and 2011 nec solar labeling requirements.
Field applied hazard markings.
690 12 is the part of the nec that specifies the rapid shutdown requirements.
Building inspector s guide nec 690 pv labeling requirements the nec690 building inspector s guide is a set of reference materials developed for building inspectors and ahj officials as it relates to article 690 of the national electrical code nec 2014 for photovoltaic warning labels.
Section 690 of the nec solar photovoltaic pv systems includes all information regarding solar systems.
The new language listed in 690 56 c will require a label that is similar in concept to the two examples below.
Ansi all labels identified in the 2017 nec are associated with this statement.
2020 nec labeling requirements.
Where caution warning or danger signs or labels are required by this code the labels shall meet the following requirements the marking shall adequately warn of the hazard using effective.
Section location of label label text and appearance section location of label label text and appearance 690 54 all interactive system s points of interconnection with other sources shall be marked at an accessible location at the disconnecting means as a power.
Though ahjs may take months or years to adopt the latest edition california won t adopt the 2017 nec until 2020 it s important for solar contractors to know what s coming.
These changes will have meaningful impacts on the design criteria of residential and commercial solar installations alike.
This assortment pack of pv labels is designed to meet 2017 nec code requirements and includes 55 high quality labels.
In an effort to simplify design requirements nec 2017 removed 690 35 which provided unique requirements for ungrounded systems.
All labels are printed on premium 3 5mm white vinyl with permanent adhesive and uv sunlight resistant laminate for years of outdoor use.
The 2017 triennial update of the national electrical code nec is complete and has been released for adoption.
If you live in an area of the country that is under nec 2014 the code calls for the rapid shutdown switch to reduce the voltage to 30 v within ten seconds.
Labeling for ungrounded systems another change revolves around power labels.